Product Information
The Triplett Model 9055 is a 3-3/4 digit (4000 count) high performance digital multimeter with an array of environmental functions. It offers over 50 measurement ranges including AC/DC Voltage, AC/DC Current, Resistance, Frequency, Capacitance, Temperature (Type K and ambient), Relative Humidity (RH), Light (LUX), and Sound (dBC). Additional features include an NCV Detector, Continuity, and Diode Test. The rubberized overmolded housing with built-in stand provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximize battery life. With an industry leading CAT IV design, it provides superior resistance to damage from transient overvoltages in any demanding industrial settings. The Model 9055 is suited for a variety of industrial and residential applications such as security, home theater, electrical, HVAC installations and more. Includes test leads, alligator clips, Type K Temperature probe and 9V battery. 2year warranty.
CATEGORY: DIGITAL MULTIMETER
- 53 measurement ranges with Relative Humidity, Light (LUX), and Sound (dBC) measurement
- Temperature (Type K and ambient), Frequency and Capacitance measurement
- Includes test leads, alligator clips, Type K Temperature probe and 9V battery
- Double molded splash proof, dust proof, drop resistant case with built-in stand and CAT IV 600V safety rating
Triplett Solutions for Every Contractor
53 Measurement Ranges
The 9055 Digital Multimeter offers conventional multimeter measurement features, including AC and DC Voltage and Current, Resistance, Continuity, Diode Test, Capacitance, Frequency, and Duty Cycle.
Well suited for use in all test environments, from occasional use in residential applications to everyday use by installers, home theater technicians, security technicians, electricians, HVAC technicians, and other professionals in the industry.
- 53 measurement ranges with Relative Humidity, Light (LUX), and Sound (dBC) measurement
- Temperature (Type K and ambient), Frequency and Capacitance measurement
- Includes test leads, alligator clips, Type K Temperature probe and 9V battery
The overmolded housing provides impact and drop resistance in a sleek ergonomic package, while the convenient Auto Power Off feature maximizes battery life.
- Double molded splash proof, dust proof, drop resistant case
- Built-in stand
- Rugged Design and Auto Power Off
Triplett Solutions for Every Contractor
|
|
|
|
|
|---|---|---|---|
Non-Contact Voltage SensorBuilt-in Non-Contact Voltage Sensor detects and indicates the presence of dangerous AC voltages. CAT IV design provides superior resistance to damage from transient overvoltages, such as those experienced in demanding industrial settings. |
Light LevelThe Light Level function measures illumination in Lux on two ranges. Its silicon sensor is very stable and fully cosine-corrected for the angular incidence of light. |
Ambient Temp & Humidity MeterTemperature is measurable in the meter itself or at the tip of the provided temperature probe. Relative Humidity is measured and displayed continuously along with the room temperature, providing a convenient reference for all other measurements. |
Sound LevelThe dBC Sound Level function is useful for measuring noise in factories, offices, homes, and other settings, as well as for checking the acoustics of studios, auditoriums, home theater installations, and more. |
|
|
||||
|---|---|---|---|---|
| 9065 DMM | 9055 DMM | 9045 Autoranging DMM | 9007-A Manual DMM | |
| True RMS | True RMS | Averaging | True RMS | Averaging |
| Basic Accuracy | +/-0.03% | +/-1.5% | +/-0.5% | +/-0.5% |
| AC/DC Voltage | 0.001mV to 1000V / 0.001mV to 1000V | 0.1mV to 700V / 0.1mV to 1000V | 1mV to 750V / 0.1mV to 1000V | 1mV to 600V / 0.1mV to 600V |
| AC/DC Current | 0.1µA to 10A / 0.1µA to 10A | 0.1µA to 10A / 0.1µA to 10A | 0.1µA to 10A / 0.1µA to 10A | 1µA to 10A / 1µA to 10A |
| Resistance (Ohms) | 0.01 to 60M | 0.1 to 40M | 0.1 to 60M | 0.1 to 20M |
| Temperature | -40 to 1832° F | -4 to 1400° F | -4 to 1400° F | -4 to 1400° F |
| Capacitance | 0.001nF to 60mF | 10pF to 100µF | 10pF to 4000µF | 1pF to 200µF |
| Frequency | 0.001Hz to 60MHz | 0.001Hz to 10MHz | 0.001Hz to 10MHz | 1Hz to 2000Hz |
| Duty Cycle | 10 to 90% | 5 to 95% | 0.1 to 99.9% | No |
| Safety Category | CAT IV-600V | CAT IV-600V | CAT III-600V | CAT III-600V |
| Specifications | Range |
| Auto/Manual Ranging | Autoranging |
| True RMS/Averaging | Averaging |
| Basic Accuracy | ±1.5% |
| AC Voltage | 0.1mV to 600V |
| DC Voltage | 0.1mV to 600V |
| AC Current | 0.1µA to 10A |
| DC Current | 0.1µA to 10A |
| Resistance | 0.1Ω to 40MΩ |
| Ambient Temperature | 32 to 122°F (0 to 50°C) |
| Type K Temperature | -4 to 1400°F (-20 to 750°C) |
| Relative Humidity | 33 to 99%RH |
| Capacitance | 10pF to 100µF |
| Frequency | 0.001Hz to 10MHz |
| Light | 1 to 40,000Lux |
| Sound Level | 35 to 100dB (C weighting, fast response) |
| Duty Cycle | 5 to 95% |
| NCV Detector | 50 to 1000VAC |
| Safety Category | CAT IV-600V |
| Dimensions | 6.7 x 3 x 1.8" (170 x 76.2 x 45.7mm) |
| Weight | 11.2oz (317g) |
- 1 - 6-in-1 Autoranging Digital Multimeter (9055)
- 1 - Set of Test Leads
- 1 - Type K Thermocouple Probe
- 1 - 9V Battery
- 1 - Instruction Manual